| dc.contributor.author | Masse', Vincent | |
| dc.contributor.author | Ghate, Raju S | |
| dc.date.accessioned | 2021-12-01T20:00:02Z | |
| dc.date.available | 2021-12-01T20:00:02Z | |
| dc.date.issued | 2021-03-15 | |
| dc.identifier.citation | DOI: 10.1080/24699322.2021.1894239 | en_US |
| dc.identifier.uri | ${sadil.baseUrl}/handle/123456789/935 | |
| dc.description | article; 11 p. | en_US |
| dc.description.abstract | X-Atlas TM is a new imaging technology intended to advance the state of the art in patient-specific instrumentation. It uses standard AP and lateral radiographs instead of CT or MRI scans to create 3D bone models, which can be used to perform pre-operative surgical planning and fabricate TKA personalized guides. The aim of this study was to validate X-Atlas TM and evaluate the accuracy of personalized guides created with this imaging technology. Its ability to predict implant size was also determined. The accuracy of the X-Atlas TM imaging technology was evaluated by comparing the landmarks of X-Atlas TM 3D Bone models to MRI-reconstructed bone models. The accuracy of PSI guides created with X-Atlas TM (X-PSITM guides) was evaluated during a validation study (16 specimen knees) and a clinical study (50 patients; Health Canada #CSU2015-12K). Optical navigation was used to measure positioning accuracy. In addition, the ability of X-Atlas TM to predict implant size was assessed. The accuracy of the X-Atlas TM imaging technology was below 0.87 and 1.28 mm for the femoral and tibial landmarks, respectively. The accuracy of X-PSITM guides to reproduce the pre-operative planned HKA was within ± 3 in 100% and 86.1% of cases, for the laboratory and clinical study respectively, which was significantly better than historical data for conventional instrumentation. X-Atlas TM was able to predict implant size to ± 1 size in 95.6% and 100%, for the femur and tibia component respectively. The X-Atlas TM imaging technology demonstrated excellent accuracy for reconstructing a 3D bone model. The results show that PSI guides created with X-Atlas TM (X-PSITM guides) provide greater implant positioning accuracy than conventional instrumentation, without the requirement of advanced imaging. Furthermore, the X-Atlas TM imaging technology could effectively predict implant sizing, potentially reducing the number of instrument trays and improving surgical efficiency. | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | Informa UK Limited, Taylor & Francis | en_US |
| dc.relation.ispartofseries | Computer Assisted Surgery;26:1, 31-40 | |
| dc.subject | Patient-specific instrumentation | en_US |
| dc.subject | total knee arthroplasty | en_US |
| dc.subject | x-ray | en_US |
| dc.subject | radiographs | en_US |
| dc.subject | alignment | en_US |
| dc.title | Using Standard X-ray images to create 3D digital bone models and patient-matched guides for aiding implant positioning and sizing in total knee arthroplasty. | en_US |
| dc.type | Article | en_US |